Anritsu MT8850A Bluetooth Headset User Manual


 
Specification MT8850A / MT8852A Bluetooth Test Set
13000-000109 C-11
June 2003
MT8850A/MT8852A Measuring Receiver
Frequency
Range 2.40 to 2.5 GHz
Resolution 1 kHz
Settling time <160µs to 75 kHz during the establishment of a link. When a link has
been established and the EUT has been placed into test mode, the
MT8850A/MT8852A receiver is pre-tuned to ±1 kHz of the nominal
channel frequency.
Accuracy As frequency standard ± 25 Hz
Measurement
channel
bandwidth
2 MHz 3dB bandwidth, flat response Fc ± 550 kHz, and 1.3 MHz
3dB bandwidth, flat response Fc ± 550 kHz.
Level
Range +22 dBm to -55 dBm average power
Power
measurement
accuracy
±1 dB (+20 dBm to -35 dBm)
Input VSWR 1.5:1
Damage level +25 dBm
Resolution 0.1 dB
Modulation
Modulation GFSK
Deviation
measurement
range
0 to 350 kHz peak
Accuracy 1 kHz
EUT Control Interface
The EUT control interface provides RS232 HCI commands to EUT through a standard
RS232 interface. The interface meets the requirements of Bluetooth V1.1 specification for
HCI UART transport layer. An RS232 cable is supplied.
The EUT control interface provides USB HCI commands to EUT through a standard USB
interface. The interface meets the requirements of Bluetooth V1.1 specification section
H:2. A USB cable is supplied (MT8852A only).