5
GETTING STARTED USING THE SYSTEM APPENDIX
SETTING THE SYSTEM
Title Sub title Item Sub item Setting range Default
System setting Advanced station
settings
Video door
station/Audio
door station/
Room sub
station
Called
stations
Call priority Normal/Priority/Urgent Normal
Called stations (Set up to 20 master stations from the
registered ones.)
-
Contact input
(room sub
stations only)
Contact type Normally open (NO)
/Normally closed (NC)
Normally open
(NO)
Call priority/Answering
the page
Answering the page
/Call (Normal/Priority/Urgent)
Normal
Other
Transmit volume boost
at PTT
ON/OFF
(ON: approx. +6dB up)
OFF
Camera zoom image
preset (video door
stations only)
0 (wide)/1/2/3/4/5/6/7/8/9 (zoom) 5 (Center)
Call acknowledge tone
on/off
ON/OFF ON
Backlight adjustment
(video door stations
only)
Exposure +/Exposure - Exposure +
Speaker
(room sub stations only)
Built-in speaker
/External speaker
Built-in
speaker
Master station Stations to be scan monitored (Select up to 20 sub stations from the
registered ones.)
-
Other
Master station function:
paging, chime, monitor,
door release, and
remote site call
ON/OFF ON
Central
control unit
Contact input
(Contact input) S1 to S4 S1
Contact type
Normally open (NO)
/Normally closed (NC)
Normally open
(NO)
Trigger condition None/Broadcast chime/Stop chime None
Sound source
(Only when "Broadcast
chime" is selected at
"Trigger condition")
Internal sound source (Select a
sound fi le or sequence name from the
registered ones in the list.)
/External sound source (Select either
External sound source 1 or 2.)
-
Chime priority
(Only when "Broadcast
chime" is selected for
"Trigger condition")
Normal/Priority/Urgent Normal
Zone name
(Only when "Broadcast
chime" is selected at
"Trigger condition")
(Select from the registered ones.) -
Contact output
(Contact output terminal)
L1 to L8 L1
Contact type
Normally open (NO)
/Normally closed (NC)
Normally open
(NO)
Trigger condition None/Calling notice/Door release
/External sound source/PA output
None
Calling notice
(Only when "Calling
notice" is selected at
"Trigger condition")
Normal: OFF/ON
Priority: OFF/ON
Urgent: OFF/ON
Normal: OFF
Priority: OFF
Urgent: OFF
Door release
(Only when "Door
release" is selected at
"Trigger condition")
(Select from the sub stations registered
and set for the central control unit.)
-
External sound source
(Only when "External
sound source" is
selected at "Trigger
condition")
External sound source 1
/External sound source 2
-
PA output
(Only when "PA output"
is selected at "Trigger
condition")
PA output 1 to 4 -