Aiphone IS Series Intercom System User Manual


 
12
Registering areas
[System setting – Area registration]
Required
Register areas for separating stations in the system. The
number to which a name is entered is registered as an area
number. Up to 99 areas can be registered.
Click
1
Area registration in the table of contents.
Enter an area name in the cell for the area number 01.
2
The gures under "Number" in the tables means the area
*
numbers.
Enter area names in the cells for other numbers to
3
register more areas.
Click
4
Temporarily stored
to save the current setting
results temporarily.
If you wish to cancel the setting results you have made,
*
click a title in the table of contents or “Refresh” in the
web browser menu.
NOTES:
Be sure to register at least one area to the area number 01.
(“1” is entered in the cell for the area number 01 as default.)
A call number displayed on the master station monitor consists of
an area number plus a station number.
Registering zones
[System setting – Zone registration]
Register zones for paging (transmitting announcements and
chime). The number to which a name is entered is registered
as a zone number. Up to 99 zones can be registered.
* Zones are groups of stations designated for paging and chime
paging.
Click
1
Zone registration in the table of contents.
Enter a zone name in the cell for the target zone
2
number.
The gures under "Number" in the table means the zone
*
number.
Enter zone names in the cells for other numbers to
3
register more zones.
Click
4
Temporarily stored
to save the current setting
results temporarily.
If you wish to cancel the setting results you have made,
*
click a title in the table of contents or “Refresh” in the
web browser menu.
Registering control units [System setting
– Control units composition]
Register all the control units connected to the central control
unit.
Click
1
Control units composition in the table of
contents.
Click to check the radio button under "Connected" for
2
the unit you will register.
Click
*
Connection check
to con rm the connected units.
Connected: yellowish green
Not connected: gray
Shows a port no. of the central control unit to connect with
a room sub control unit or add-on control unit.
Shows the ID setting of the room sub control unit or add-
on control unit set by the ID setting switches. (Refer to the
INSTALLATION MANUAL for details.)
Click
3
Temporarily stored
to save the current setting
results temporarily.
If you wish to cancel the setting results you have made,
*
click a title in the table of contents or “Refresh” in the
web browser menu.