SETTING THE SYSTEM
Registering stations and PA outputs
[System setting – Registering stations]
Register all the stations and PA outputs connected in the
system, and set the area, station no., station name (or PA
output name) and type of station (for sub stations: video door/
audio door/room sub stations) to them.
Click
1
Registering stations in the table of contents.
Set the area, station no., station name and type of
2
station (for sub stations) to the target stations, and
enter names to the target PA outputs.
Setting the station no. is required.
*
Shows a port no. of the control unit to connect with a
*
station.
It is required to enter a name to the target PA
*
output when an external unit is connected to the
corresponding PA output terminals.
For a cell with the
*
mark, select the target one from the
pull-down menu.
Do not set stations with the same number in an area.
*
NOTE:
The name of a master station displayed on its monitor in standby
mode is up to 16 alphanumeric characters.
Other buttons
Connection check
Click to con rm the connected units.
Connected: yellowish green
Not connected: gray
Station type error: pink
[Collective setting]:
The following buttons are used to make the settings to all
the checked stations at one time.
Pressing each button opens another window.
*
NOTE:
Be sure to check all the target stations before using these
buttons.
Area
Click to set the same area number to all the checked
stations.
Station number
Click to assign sequential numbers to all the checked
stations from top to bottom. The number you enter will
be set as the rst number and will be assigned to the top
station of the ones checked. Other checked stations will
be numbered sequentially.
Station name
Click to assign the same station (and/or PA output) name
and sequential numbers to all the checked stations (and/
or PA outputs) from the top down. Enter a name only.
Station type
(sub stations)
Click to set the same station type to all the checked sub
stations.
How to select multiple stations
Click to check the stations and PA outputs you will
register.
By clicking the button for the control unit, all the stations
and PA outputs connected to it are checked or canceled.
By clicking the button on the top of the list, you can
check or cancel all the stations and PA outputs on the
list.
Click
3
Temporarily stored
to save the current setting
results temporarily.
If you wish to cancel the setting results you have made,
*
click a title in the table of contents or “Refresh” in the