Total Access 600 Series System Manual Section 4 User Interface Guide
61200624L1-1B © 2004 ADTRAN, Inc. 75
I
NTERFACES
(N
ETWORK
SHDSL)
View the network SHDSL interface status and configure SHDSL parameters from this menu. These menus
are only applicable to SHDSL Total Access 600 Series systems.
INTERFACES (SHDSL) > CONFIG
Configure the various SHDSL parameters.
INTERFACES (SHDSL) > CONFIG > NTU/LTU MODE
Choices are
NTU
(Network Terminating Unit) or
LTU
(Line Terminating Unit). Select
NTU
when the unit
is connected to the SHDSL network device. Select
LTU when the unit is expected to function as the
SHDSL network device. In back-to-back applications, one unit must be set to
NTU and the other for LTU.
INTERFACES (SHDSL) > CONFIG > ANNEX = A/B
Configures the G.shdsl signaling method as either A
NNEX
A or A
NNEX
B. Total Access 600 Series units also
support an auto detection signaling method (
A
NNEX
A&B) which allows the unit to detect the signaling
method on the link and signal accordingly.
INTERFACES (SHDSL) > CONFIG > ITU-T/GSPAN V1.2
Configures the G.shdsl signaling as either standard ITU-T or G
LOBESPAN
V
1.2.
INTERFACES (SHDSL) > CONFIG > RADSL (AUTO/FIXED)
Configures the SHDSL interface to be either variable rate speeds (A
UTO
) or a fixed rate (F
IXED
). If the
system is configured for a fixed rate, the link will only train at the specified rate. The DSLAM setting must
match the configured rate when using fixed rates.
INTERFACES (SHDSL) > STATUS
Displays the SHDSL interface status including configuration modes and data rates.
INTERFACES (SHDSL) > STATUS > TRAINING STATE
Indicates the current training state for the SHDSL interface as either trained, currently training, etc.
INTERFACES (SHDSL) > STATUS > NTU/LTU MODE
Displays the current configured mode of operation on the SHDSL link as either NTU or LTU.
INTERFACES (SHDSL) > STATUS > DATA RATE
Displays the negotiated data rate on the SHDSL link.
INTERFACES (SHDSL) > STATUS > FRAME MODE
Displays the framing of the SHDSL link as either framed or unframed.