ADTRAN 606 Telephone User Manual


 
Section 5 DLP-1 Total Access 600 Series System Manual
186 © 2004 ADTRAN, Inc. 61200624L1-1B
1. Connecting a VT100 terminal to Total Access 6XX:
2. Connect a PC emulating a VT-100 terminal to Total Access 6XX.
Most personal computers (PCs) or laptops can run communications software that emulates a VT100
terminal. Examples include Windows programs such as Terminal
or Hyperterminal
. However,
there are many other adequate, commercially available software packages which will allow your PC or
laptop to emulate a VT100 terminal.
You are now ready to log in to the Total Access 6XX, as described in DLP-2, Logging in to the System.
Perform the steps below in the order listed.
Set the parameters of the VT100 terminal or PC to:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
If the terminal has a parallel setting, disable it and use the serial port.
Using the
CRAFT
Port
Plug the RJ-48 end of the data cable into the Total Access 6XX CRAFT port on the back of
the unit. Make the connection to the VT100 terminal as appropriate for your equipment.
Set the parameters of the communications software to:
9600 baud rate
8 data bits
No parity
1 stop bit
No flow control
Set the PC for direct connect on the appropriate com port (instead of dial up connection).
Using the
CRAFT
Port
Plug the RJ-48 end of the data cable into the Total Access 6XX CRAFT port on the back of
the unit. Make the connection to the VT100 terminal as appropriate for your equipment.