SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > IDLE TIME
This option defines the amount of time in minutes user may stay connected without any activity on the
CRAFT
port before the user is automatically logged out of the system. A value of
0
disables this inactivity
timer function enabling users to stay connected until manually logged out. The value range is
0 (def) to 255
(minutes).
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > BAUD RATE
This is the asynchronous rate that the CRAFT
port will run. The possible values are
300, 1200, 2400, 4800,
9600, 19200, 38400
, 57600, and 115200. The default value is 9600. The unit and the VT100 terminal or
PC with terminal emulation software must be set for the same baud rate.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > DATA BITS
The number of data bits that the CRAFT port sends in a frame. The possible values are 7 or 8 (def) bits. The
unit and the VT100 terminal or PC with terminal emulation software must be set for the same number of data
bits.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PARITY
This is the asynchronous parity that the CRAFT
port will run. The possible values are
N
ONE
(def), O
DD
, or
E
VEN
. The unit and the VT100 terminal or PC with terminal emulation software must have the same parity
setting.
SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > STOP BITS
This is the number of stop bits used for the CRAFT
port. The possible values are
1 (def), 1.5 or 2. The unit
and the VT100 terminal or PC with terminal emulation software must have the same number of specified
stop bits.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS
Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 6XX
supports up to five simultaneous Telnet sessions.
Table 2. Instructions for Changing Passwords
Step Action
1
Select the P
ASSWORD
field—a new P
ASSWORD
field displays.
2
Type the new password in the E
NTER
field.
3
Type the new password again in the C
ONFIRM
field.
The Total Access 6XX ships with default Telnet Access parameters of: guest (user),
password (password). Change this password during the initial configuration to protect
your unit.