Multi-Tech Systems MVP-2410/3010 IP Phone User Manual


 
Quick Start Instructions MultiVOIP User Guide
60
Once you’ve begun using the web browser GUI, you can go back to
the MultiVOIP Windows GUI at any time. However, you must log
out of the web browser GUI before using the MultiVOIP Windows
GUI.
5. Go to Configuration | Voice/Fax. Select Coder | “Automatic.” At
the right-hand side of the dialog box, click Default. If you know any
specific parameter values that will apply to your system, enter them.
Click Copy Channel. Select Copy to All. Click Copy. At main
Voice/Fax Parameters screen, click OK to exit from the dialog box.
6. Enter telephone system information.
Analog MultiVOIPs
MVP-130/130FXS,
MVP-210/410/810
Digital MultiVOIPs
MVP-2410/3010
Go to
Configuration | Interface.
Enter parameters obtained
from phone company or
PBX administrator.
Go to
Configuration | T1/E1/ISDN.
Enter parameters obtained
from phone company or
PBX administrator.
ISDN-BRI MultiVOIPs
MVP-410ST/810ST
Go to Configuration | ISDN BRI.
Enter parameters obtained from phone company
or PBX administrator.
If the voip is connected to BRI extensions of a PBX
or a phone company, then select "Terminal"
in the ISDN BRI Parameters screen.
If the voip is connected to ISDN terminal adapters
and/or ISDN phones, then select "Network"
in the ISDN BRI Parameters screen.
7. Go to Configuration | Regional Parameters. Select the
Country/Region that fits your situation. Click Default and confirm.
8. Go to Configuration | Regional Parameters. In the Country
Selection for Built-In Modem field (drop-down list), select the
country that best fits your situation. (This may not be the same as
your selection for the Country/Region field. The selections in the
Country Selection for Built-In Modem field entail more detailed