Linksys SPA 900 IP Phone User Manual


 
2-19
Linksys IP Phone Administrator Guide
Firmware Version 5.1
Chapter 2 Getting Started
Using the Interactive Voice Response Interface
Note The items marked with “Requires Password” require a password only if the Administrator password is
set.
Entering a Password through the IVR
To input the password using the phone keypad, the following translation convention applies:
To input: A, B, C, a, b, c—press “2
To input: D, E, F, d, e, f—press “3
To input: G, H, I, g, h, i—press “4
To input: J, K, L, j, k, l— press “5
To input: M, N, O, m, n, o—press “6
To input: P, Q, R, S, p, q, r, s—press “7
To input: T, U, V, t, u, v—press “8
To input: W, X, Y, Z, w, x, y, z—press “9
To input all other characters in the Administrator account password, press “0
Note This translation convention applies only to the password input.
Manual Reboot of Unit 732668 None After you hear “Option Successful,” hang
up. Unit reboots automatically.
User Factory Reset of
Unit
WARNING:
ALL “User-Changeable”
NON-DEFAULT
SETTINGS WILL BE
LOST!
This might include
network and service
provider data.
877778 Enter 1 to confirm
Enter *(star) to cancel
operation
SPA prompts for confirmation. After
confirming, you hear “Option
Successful.” Hang up. Unit reboots and
all “User Changeable” configuration
parameters are reset to factory default
values.
Factory Reset of Unit
WARNING:
ALL NON-DEFAULT
SETTINGS WILL BE
LOST!
This includes network and
service provider data.
73738 Enter 1 to confirm
Enter * (star) to cancel
operation
SPA prompts for confirmation. After
confirming, you hear “Option
Successful.” Hang up. Unit reboots and
all configuration parameters are reset to
factory default values.
Table 2-2 IVR Options (continued)