Installing and Configuring PPU Software
Getting Started
Chapter 324
Getting Started
Factory Integrated
Systems
You do not need to install the PPU B.06.x software if your processors and
software were ordered with your HP enterprise server in (or after)
January 2003. The PPU software was already installed by HP prior to
delivery. However, initially you need to configure the PPU software to
communicate with the utility meter.
NOTE The PPU B.06.x software must be installed and configured on every
partition in your system, including virtual partitions.
There are three steps you can perform to verify your PPU system has the
PPU B.06.x software installed and configured for communication with
the utility meter:
Step 1. Verify the PPU software is installed by executing the following
command:
/usr/sbin/swlist | grep T2351AA
You should see output similar to:
T2351AA B.06.04 HP-UX Pay Per Use (PPU)
If you do not receive the correct result for Step 1 (above) see “Installing
PPU Software” on page 26 for PPU software installation details.
Step 2. Verify the PPU software is configured to use the utility meter and the
https connection is functional by executing the following command:
/usr/sbin/ppuconfig -t
You should see output similar to:
Round trip communication with the utility meter succeeded.
If you do not receive the correct result for Step 2 (above) see “Configuring
PPU Software” on page 29 for PPU software configuration details.