CyberData 11111 Intercom System User Manual


 
Operations Guide 930500E CyberData Corporation
27
Installing the VoIP V3 Indoor Intercom
Configure the Device
2. On the Device Configuration page, you may enter values for the parameters indicated in
Table 2-7.
Table 2-7. Device Configuration Parameters
Web Page Item Description
Volume Settings
Speaker Volume Type the desired Intercom volume level into this field.
Microphone Gain Type the desired microphone gain level into this field.
Relay Settings
Activate Relay with DTMF Code When selected, the relay can be activated with a DTMF
code.
DTMF Activation Code Type the desired DTMF activation code
(25 character limit).
DTMF Activation Duration (in seconds) Type the desired DTMF activation duration (in seconds) (2
character limit [activation times now go up to 99 seconds]).
NOTE: A DTMF activation duration of 0 will toggle the
relay indefinitely or until the activation code is sent again
Activate Relay During Ring When selected, the relay will be activated for as long as
the call is active.
NOTE: When the phone is set to Auto Answer, it will not
ring and this option does nothing.
Activate Relay During Night Ring Check this box to activate the relay for as long as a Night
Ring tone is ringing.
Activate Relay While Call Active When selected, the relay will be activated for as long as
the call is active.
Activate Relay on Button Press When selected, the relay will be activated when the Call
Button is pressed.
Relay on Button Press Timeout (in seconds) Type the desired time (in seconds) that you want the relay
to activate after the Call Button is pressed (1 character
limit).
Miscellaneous Settings
Auto-Answer Incoming Calls When selected, the device will automatically answer
incoming calls.
When Auto Answer is Off, the device will play a ringtone
through the Intercom speaker until someone presses the
button.
Button Lit When Idle When selected, the Call Button remains lit when idle.
Play Ringback Tone When selected, you will hear a ringback tone while making
a call.