MC50 Integrator Guide3-16
The UBC’s charge LEDs show the status of the battery charging in the adapter. Table 3-3 shows battery charging status indications.
The standard battery fully charges in approximately 2.5 hours and the extended capacity battery fully charges in approximately six
hours.
Figure 3-15. UBC Adapter LEDs
Table 3-3. UBC Adapter Charge LED Status Indications
LED Indication Description
POWER Red Power is connected to the UBC Adapter.
READY Green Charging complete.
CHARGING or
STANDBY or
FAULT
Yellow Normal charge.
Flashing Yellow The battery was deeply discharged and is being trickle charged to bring the voltage up to the operating level. After
operating level voltage is achieved the battery charges normally.
Flashing Yellow Charging error, check placement of mobile computer/spare battery.
POWER
READY
CHARGING or STANDBY or FAULT
(Green)
(Flashing Yellow)
(Solid Yellow)
(Flashing Yellow)