SpectraLink 150 M3 MCU Telephone User Manual


 
SpectraLink Corporation Link WTS Installation and Operation
Part Number: 72-0075-01-C-W.doc Page 22
Switch Interface Line LEDs MCU Type Notes
Analog 1 SCA The SCA will only support Analog
Comdial 3 SCU
DEFINITY - 2 wire 1,4 SCU
DEFINITY - 4 wire 1,5 SCF
Executone 2,5 SCB
Fujitsu 2,4 SCU
Inter-Tel 2,3,4 SCU
Meridian 1,2 SCU
Merlin Legend 1,3 SCF
Mitel 1,2,3 SCX The SCX will only support Mitel
NEC 1,2,4 SCU
Norstar 2 SCU
Panasonic 5 SCP
Siemens / Rolm 4 SCU
Toshiba 2,3 SCU-5XX
Unconfigured 1 through 8
6. Move the Mode Switch back to NORMAL.
7. The MCU will cycle through diagnostic testing. When the system is ready for
use, the error LED should be off, and the LED for the MCU Number (1-4) will be
lit. This should take less than two minutes.
If the LED for the MCU ID does not light, or if an MCU ID is duplicated, there is
most likely a problem with the IPC cabling. If the system displays an error refer
to 8.1 Troubleshoot Error Codes.
8. If you select a switch type that is not supported by the MCU type, the system will
alarm. The Error LED will flash along with Status LEDs 4 and 5. For example,
this alarm will display if you assign switch type NEC to an SCB-5XX
Executone MCU.
If this alarm displays, use the table above to verify that your MCU type supports
the selected switch type. If you need to change the switch type, repeat steps 2
through 6.