35
PJ-Net Organizer
OWNER’S MANUAL
Power on/off the projector
ENGLISH
Items Description
Accumulated lamp-use time It displays in 1 hour units (h)
When resetting the lamp counter, this time will be reset to 0.
Accumulated projector-use time It displays the accumulated used time in an hour unit (h). This
cannot be reset.
Power status It displays the status of the lamp, OFF, On starting up, ON, On
cooling down or On power management operating.
Projector condition It displays the condition of the projector's power, Normal,
Power Failure, Temperature Error, Normal after temperature
over.
Input status It displays the selected input mode, signal mode and signal
status.
Internal temperature It displays the temperature at internal thermal sensors in
degrees. The icons [A], [B] and [C] on the page represent the
thermal sensors located in the projector. If the temperature at
one of those sensors exceeds specified temperature, the
appearance of its icon changes to the following alert icon to let
users know about the abnormal temperature. Please check
surrounding temperature of the projector, check for clogged air
filters and check area surrounding the ventilation fans.
Check the status of projector
In the "Power & Status" page, you can control the projector power, and also you can
check the status of the projector as follows:
The icons [A], [B] and [C] rep-
resent the sensors located in
the projector as follows:
[A]: Surrounding temperature
of the projector *
[B]: Surrounding temperature
of the lamp
[C]: Surrounding temperature
of the panels
*