Polycom 1725-11530-310 IP Phone User Manual


 
Administrator’s Guide SoundPoint IP / SoundStation IP
A - 54
Alert Reports <alert/>
This configuration attribute is defined as follows:
Attribute
Permitted
Values Default Interpretation
voice.qualityMonitoring.collector.
alert.moslq.threshold.warning
Null, 15 to 40 Null Threshold value of listening MOS
score (MOS-LQ) that causes phone
to send a warning alert quality
report. Configure the desired MOS
value multiplied by 10. If set to Null,
warning alerts are not generated
due to MOS-LQ.
For example, a configured value of
35 corresponds to the MOS score
3.5.
voice.qualityMonitoring.collector.
alert.moslq.threshold.critical
Null, 15 to 40 Null Threshold value of listening MOS
score (MOS-LQ) that causes phone
to send a critical alert quality report.
Configure the desired MOS value
multiplied by 10. If set to Null,
critical alerts are not generated due
to MOS-LQ.
For example, a configured value of
28 corresponds to the MOS score
2.8.
voice.qualityMonitoring.collector.alert.
delay.threshold.warning
Null, 10 to
2000
Null Threshold value of one way delay
(in ms) that causes phone to send a
critical alert quality report. If set to
Null, warning alerts are not
generated due to one way delay.
One-way delay includes both
network delay and end system
delay.
voice.qualityMonitoring.collector.alert.
delay.threshold.critical
Null, 10 to
2000
Null Threshold value of one way delay
(in ms) that causes phone to send a
critical alert quality report. If set to
Null, critical alerts are not generated
due to one way delay. One-way
delay includes both network delay
and end system delay.