Philips DBS-EX23-530 Telephone User Manual


 
Programming Reference Special ISDN Function Codes
Revised April 2000 DBS-EX23-530 4-37
Parameter Remote Loopback
Description This command only applies to a DBS within a private network.
The command is entered at one DBS in order to loopback through
another DBS.
For example, to initiate a loopback from DBS “B” to DBS “A,”
this command would be entered at DBS “B.” In order for the loop-
back to work, DBS “A” must have the “Remote Loopback” option
turned on in system programming.
Notes:
1. The clock source of the DBS that issues this command must be
set to “free run.”
2. Before executing this command, you must first enter the pro-
gramming authorization code (#98 9999). This command only
applies to a DBS within a private network.
The command is entered at one DBS in order to loopback through
another DBS.
For example, to initiate a loopback from DBS “B” to DBS “A,”
this command would be entered at DBS “B.” In order for the loop-
back to work, DBS “A” must have the “Remote Loopback” option
(page 4-37) turned on in system programming.
Notes:
1. The clock source of the DBS that issues this command must be
set to “free run.”
2. Before executing this command, you must first enter the pro-
gramming authorization code (#98 9999).
Execution Master: ON/OFF #94 3 (0 or 1)
Slave: ON/OFF #95 3 (0 or 1)
Options
0=Off
1=On
Parameter AIS Signal Transmission
Description Transmits an AIS signal (all 1s) to the CO.
Note:
Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Execution Master: ON/OFF #94 4 (0 or 1)
Slave: ON/OFF #95 4 (0 or 1)
Options
0=Off
1=On