Philips DBS-EX23-530 Telephone User Manual


 
Special ISDN Function Codes
Programming Reference
4-38 DBS-EX23-530 Revised April 2000
Parameter Forced Re-synchronization
Description Re-synchronizes the DBS ISDN with the public network.
Notes:
1. Forced re-synchronization disconnects existing calls.
2. Before executing this code, you must first enter the program-
ming authorization code (#98 9999).
Execution Master: ON/OFF #94 6
Slave: ON/OFF #95 6
Options None. Re-synchronization begins as soon as the code is entered.
Parameter Historical Error Clearance
Description Clears the error counters for the following alarms:
• yellow
• red
• framing loss
• slip rate
loss of signal
• sync loss
Note:
Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Execution Master: ON/OFF #94 7
Slave: ON/OFF #95 7
Options None. The counters are cleared as soon as the code is entered.
Parameter Alarm Relay Clear
Description Clears (opens) the alarm relay on the ISDN MDF card.
Note:
Before executing this code, you must first enter the pro-
gramming authorization code (#98 9999).
Execution Master: ON/OFF #94 8
Slave: ON/OFF #95 8
Options None. The relay is cleared as soon as the code is entered.