Maxon Telecom SP200 Two-Way Radio User Manual


 
Maxon SP200/210 Radio SP200/210
INSTALLATION, COMMISSIONING & ALIGNMENT - Issue 1.0
Page 4-8 03/01
4.5 Alignment
CAUTION
This radio contains static sensitive devices.
Static safe precautions should be observed, in
particular we would recommend the use of a
suitable floor mat, table mat, bonding cords
and a wrist strap. The soldering iron should
have an earthed tip.
Care should be exercised in the handling of
static sensitive components and they should
always be transported in the correct
containers.
Never remove, or insert, static sensitive
devices with the power applied.
4.5.1 Preparation
To perform the following tests it is necessary
to program the radio as follows:
VHF
Ch. Tx(MHz) Rx(MHz) CTCSS
1 146.025 146.025 None
2 160.025 160.025 None
3 173.975 173.975 None
4 173.975 173.975 67Hz
5 173.975 173.975 250.3
6 146.025 146.025 None
7 160.025 160.025 None
8 173.975 173.975 None
9 173.975 173.975 67Hz
10 173.975 173.975 250.3
UHF
Ch. Tx(MHz) Rx(MHz) CTCSS
1 440.025 440.025 None
2 455.025 455.025 None
3 469.975 469.975 None
4 469.975 469.975 67Hz
5 469.975 469.975 250.3
6 440.025 440.025 None
7 455.025 455.025 None
8 469.975 469.975 None
9 469.975 469.975 67Hz
10 469.975 469.975 250.3
Channel spacing as required. Channels 1 to 5
should be set to Low Power and channels 6 to
10 set to High Power.
Ensure that the Power Save is OFF.
Tests without Disassembly
Power Output, Deviation, Balance and
Squelch adjustment do not require the radio to
be disassembled.