Linear RE-2 Telephone User Manual


 
18
Call Forwarding Feature Default: OFF
The call forwarding feature will allow a visitor to contact the resident at
the programmed telephone number instead of through the local telephone
line. The feature can be set to be active during a selected Time Zone or
at all times. The telephone number programmed can contain an extension
number and an optional time delay before dialing the extension.
Press:
Forwarding Time Zone
Telephone Number Extension Delay
Forwarding: 0 = Call forwarding feature OFF
1 = Call forwarding feature ON at all times
2 = Call forwarding feature ON (scheduled by Time Zone)
3 = Forward the call if there was no resident answer
Time Zone = 1-7 (Call forwarding feature active during this Time Zone)
Telephone Number = Up to 11-digit telephone number
Extension = Up to 4-digit telephone extension number
Delay = 1-25 seconds (delay between telephone number and extension)
Example, call forwarding with only a phone number:
Press:
Telephone Number
A special feature is implemented for “Ring Down” PBX systems. If no
telephone number is programmed and call forwarding is enabled, the unit
will connect immediately without dialing.
Alternate Resident Telephone Numbers Default: All Disabled
For installations where multiple residences exist behind shared controlled
access, the RE-2 can dial three alternate telephone numbers. The visitor can
call an alternate number by entering “1#”, “2#”, or “3#” on the main keypad.
Press:
Location Enable
Telephone Number Extension Delay
Location: 1 = “1#” location; 2 = “2#” location; 3 = “3#” location
Enable: 0 = Disable; 1 = Unconditionally enable
Telephone Number: Up to 11-digit telephone number
Extension: Up to 4-digit telephone extension number
Delay: 1-25 seconds (delay between telephone number and extension)
Resident Response Telephone Keys Defaults:
Key A “1” = Activates Relay #1
Key B “2” = Activates Relay #2
Key C “9” = Disconnect Visitor’s Call
Key D “6” = Switch To/From Call Waiting
The resident response keys are the telephone keys that the resident uses to
grant access and control calls from a visitor. The keys for the four functions
can be customized. Enter all four keys each time this programming PPN is
used.
Press:
Keys ABCD
Keys ABCD: Enter 4 digits for the response keys A, B, C, & D
Key A = Activates Relay #1
Key B = Activates Relay #2
Key C = Disconnects the Visitor’s Call
Key D = Switches to and from a call holding on call waiting
Resident Programming and Command Prefi xes Defaults:
Programming = “###”
Command = “##”
The resident command prefi x is entered on a local telephone prior to
entering a command number to control one of the relays or open voice
communications with the RE-2. The resident programming prefi x is entered
on a local telephone or the main keypad prior to programming the RE-2.
Press:
Programming Command
Programming: 0 = “###”; 1 = ***”; 2 = *#*”; 3 = “#*#”
Command: 0 = “##”; 1 = **”; 2 = *#”; 3 = “#*
ADVANCED SYSTEM PROGRAMMING
Reset System Defaults
The system can be reset back to the factory defaults with this programming
PPN. EXECUTING THIS PPN WILL NOT ERASE ANY ENTRY CODES OR
TRANSMITTERS THAT HAVE BEEN PROGRAMMED.
Press:
Relay #1 On Time Default 2: Seconds
Changes the length of time Relay #1 activates when triggered.
Press:
Time
Seconds = Output time in seconds 0-60
Relay #2 On Time Default: 2 Seconds
Changes the length of time Relay #2 activates when triggered.
Press:
Time
Seconds = Output time in seconds 0-60
Main & Remote Keypad Relay and Time Zone
Default: Main Keypad = Relay #1, No Time Zone
Remote Keypad = Disabled
Sets the relay and time zone that the main and remote keypad will use.
Press:
Keypad
Relay Time Zone
Keypad: 1 = Main Keypad
2 = Remote Keypad
(Also see PPN #28)
Relay: 1 = Relay #1
2 = Relay #2
3 = Set by entry code
Time Zone: 0 = no time zone
1-7 to restrict access per time zone 1-7
NOTE: To have an entry code select which relay activates, the relay
option should be set to “3”.
Relay #2 Alternate Options Default: Access Relay
Relay #2 can be used for functions other than triggering a gate operator
or door strike. Relay #2 can be programmed to shunt alarm contacts
during Relay #1 activation or perform up to fi ve Alarm Functions. Two PPN
numbers are used to program the Relay #2 options.
Press:
Role
Role: 0 = Access Relay
1 = Alarm Shunt (Follows Relay #1 activation, used to shunt
external alarm contacts with Relay #2’s contacts)
2 = Obstacle Detector
3 = Activate during one or more of the fi ve Alarm
Functions programmed below
NOTE: More than one alarm function can be enabled at a time. Up to fi ve
digits can be entered for “Activate”.
Press:
Activate
Activate: 0 = No alarm function (default)
1 = On forced entry (activates when SENSE #1 input opens
without Relay #1 activation)
2 = On door/gate ajar (activates when SENSE #1 input stays
open for longer than one minute after Relay #1 activation)
3 = On main keypad lockout (activates when the main keypad
is in “lockout” from too many incorrect code attempts)
4 = On remote keypad lockout (activates when the remote
keypad is in “lockout” from too many incorrect code
attempts)
5 = On driveway sensor (activates when SENSE #2 input closes)