Appendix C – Specification
Alarm Dialer Interface
Two wire interface via RJ11 socket
40V feed at 12mA
Ringing voltage 40V P-P to REN4 for incoming calls
Off hook detection with dial-tone presented to alarm dialer
DTMF tone recognition for dialing outgoing calls and alarm signaling
Ethernet Interface
10Mbps and 100Mbps (10/100BaseT) with auto-negotiation
UTP with standard RJ45 socket for CAT-5 cabling
Dynamic IP addressing (DHCP) or fixed
GSM/GPRS Interface
Dual band GSM 900 MHz and DCS 1800 MHz
MMCX socket for antenna connection
IP
TCP ports (outbound): 51292 (diagnostics), 52737 (polling), 53165 (alarms)
UDP ports for upload/download 8738 and 8739
PIN Inputs
Maximum input voltage range 0V to +24V
Input ‘low’ threshold < 2V
Input ‘high’ threshold > 3V
Input pull-up impedance Internal 10K to 5V supply
Relay Outputs
Maximum operating voltage 24V
Maximum current rating 1A
Power Supply
Supply voltage 9 - 30V DC
Ethernet only (typical current) dialer on hook 145mA (supply at 12v)
Ethernet only (typical current) dialer off hook 175mA (supply ay 12V)
With GSM/GPRS (typical current) dialer on hook 185mA (supply at 12V)
With GSM/GPRS (typical current) dialer off hook 215mA (supply at 12V)
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will
also be additional transient peak current of up to 250mA required as GSM and GPRS transmissions
(e.g. for network registration and calls) are made.
Weights
Dialer unit 300g
Fully packaged
500g