6. Post installation
Once you have completed the installation you must:
Ensure the system is running correctly, the LED light on top of the unit
is on steady and alarms are being signaled to the Monitoring Centre
correctly.
After a short period of inactivity the display will switch off. To switch it
back on, touch the display anywhere.
If a fault should develop, then the LED light on the top of the unit will
start flashing and the display will show a system fault message. This
message can be touched to gain access to more information. Ensure
the user is aware of this and what action they need to take should a
fault occur.
7. PIN alarms
The IRIS Touch series have PIN inputs [18] that can be used to generate alarm
messages. These can be:
Text messages via SMS (GSM / Ethernet & GPRS only).
SIA alarm messages over IP to the Monitoring Centre (Ethernet /
Ethernet & GPRS only).
Fast Format alarm messages over IP to the Monitoring Centre
(Ethernet / Ethernet & GPRS only).
The messages for each PIN can be configured via the Settings Menu on the
touch screen display. See Appendix A for more details.