Westell Technologies IVX S-Class Cordless Telephone User Manual


 
IVX S-Class Administrator’s Manual Function 5: Voice mail programming
D.5
Function 56: Cascade notification mailboxes
Note: Not available on IVX S-Class with Integrated Answering Machine.
In addition to individual mailbox paging, IVX S-Class can support up to 10 cascade notification mailboxes
(520–529). These can be assigned to anyone who requires escalating levels of notification beyond the
single level available in all user mailboxes. In this function, you program the notification numbers and
number of times each is to be notified before the next notification number is dialed; additionally, the
mailbox owner can program these settings. To record a greeting, press PROGRAM
and the mailbox
number; then press # to confirm, and follow the prompts. The default password is the mailbox number.
Cascade mailbox options
The user can program up to three external numbers, of up to 24 digits each, to be called or paged whenever
the mailbox takes a new or urgent message. The system will dial the first number (for the number of times
listed), then dial the second paging number (for the number of times listed), and finally dial the third
number, continuing in this sequence to call all three numbers until the message has been retrieved.
1.
MB
2.
1st Number
3.
Type
4.
Attempts
5.
2nd Number
6.
Type
7.
Attempts
8.
3rd Number
9.
Type
520 2145553232 PHONE 2 2145554254 PHONE 3 2145555452 PAGER
To program this, enter:
1. The mailbox numberRange: 520–529. [Then press 1 to enter number programming, and
proceed to Step 2.]
2. First number — The number to be dialed (without the CO line group).
3. TypePHONE or PAGER. Use scroll keys to select.
4. Attempts — How many times the system will call before adding the second number.
Range: 0–99 (0 immediately pages all numbers). Default: 1.
5. Second number — The number to be dialed (without the CO line group).
6. TypePHONE or PAGER. Use scroll keys to select.
7. Attempts — How many times the system will call before adding the third number.
Range: 0–99. Default: 1.
8. Third number — The number to be dialed (without the CO line group).
9. TypePHONE or PAGER. Use scroll keys to select.
Note: Use the scroll key to enter special characters; use the
scroll key to backspace. Press # to
confirm the inserted character and continue. Press # # to complete the entry.
To change the number, delete and then re-enter it.
Cascade notification parameters
The cascade notification mailboxes will use the same CO line group and pager dialing pause as
programmed in Function 552 (see page D.4).
Notification interval
To program the notification interval parameter for a cascade notification mailbox:
1. Enter the mailbox number (520–529).
2. Press 2 to set parameters for the mailbox.
3. Enter the number of minutes for the interval between attempts.
Range: 1–1440. Default: 30.
Note: Once you change this setting from 0, you cannot reset it to 0.