SkyLink ML-001 Telephone Accessories User Manual


 
Phone Number Programming
You can program up to 6 Emergency Phone Numbers. When the system is in panic,
the control panel will call these phone numbers and announce its status.
The 6 emergency phone numbers include:
- 5 voice message phone numbers
- 1 Contact ID message phone number
Program the following for Voice Message Phone Numbers
- Phone memory (from 1 to 5), this is where the phone numbers will be stored
- Phone number, up to 29 digits.
- Redial count, this is how many times that phone number will be called, from 1
to 9 times.
- Repeat count, this is how many times the emergency message will be repeated,
from 1 to 9 times.
**Note:
You may enter a 3-second pause between digits by pressing [Mute] if needed.
You may also enter consecutive multiple pause periods. For example, you may
enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number
(123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be
a password to a paging system, or an access code for a phone dialing system.
10
INSTALLATION
You will hear [Enter
Redial].
You will hear [Enter
Repeat].
3 beeps for valid
password. 1 long beep
for invalid password.
During emergency, phone
memory 1 will be called first,
then phone memory 2, 3, 4, and
5. So phone memory 1 has
higher priority.
You will hear [Enter
phone memory].
You will hear [Phone
Accepted] indicating the
phone number and its
settings have been
programmed successfully.
Repeat is the number of times
that voice emergency message
will be played, from 1 to 9 times.
It is recommended to set up
the repeat time to 5 or more.
Redial is the number of times
that phone number will be
called. Each phone number
can have a different redial
count, from 1 to 9 times.
Phone number can be up to 29
digits.**
Enter master password to
programming mode
[1] to [9]
+ [Arm]
[1] to [9]
+ [Arm]
[1]
[1] to [5]
[PROG]
[MPIN]
[Phone
number]
+ [Arm]
Enter Repeat
count
Enter Redial
count
Enter
Programming
mode
Select phone
number
programming
Enter phone
number
Enter phone
memory
1
2
3
4
5
6
Step Keys Function Description Note
Questions Solutions
Why I can’t arm my system? Make sure none of the sensors are
triggered. You can check this by the zone
LEDs, none of them should blink.
I cannot arm the system even when no You need to disarm the system again by
sensor is triggered, and the ARM LED either entering the password or disarm by
is off. keychain remote. Although the ARM LED
is off, but the system is not completely
disarmed after an alarm was triggered.
Refer to page 22 on how to completely
disarm a control panel after an alarm has
been triggered.
Why the ARM LED keeps flashing? That means you have not programmed any
emergency phone numbers. For instructions
on how to program emergency phone
numbers, please see page 10.
How do I exit programming mode You can press the programming button on
when I’m in the middle of it? the side of the unit to quit programming
anytime.
When a sensor is triggered, the alarm You have programmed that sensor in alarm
sounds instantly even it is not armed, mode, instead of beep mode. Please refer
why is that? to page 29 for instructions of how to program
it back to beep mode.
When the alarm is triggered, why The control panel will stop calling when it
the control panel won’t call all the is disarmed by any one of the recipients.
programmed phone numbers? It Disarm can also be done locally thru the
always stops before calling the keypad on the control panel by entering a
last number. valid password.
Why the control panel doesn’t beep You have placed the buzzer mode selector
when a sensor is triggered, while on the side of the control panel to “II”, this
only the zone LED flashes? will disable the beeping. Placing it to “I” will
enable the beeping.
The control panel is in armed mode, If the triggered sensor is programmed in the
why activating a sensor will not cause Alert Zone (Bypass Zone), alarm will not
an alarm, or call any emergency phone sound, and emergency call will not be made
number? if this sensor is triggered. The control panel
will only respond when it is disarmed, in
alert mode.
TROUBLE SHOOTING
Control Panel