Panasonic S-ICX Telephone User Manual


 
72 S-ICX (International) issued October 2000 S-ICX-50-200
Overview
This chapter provides detailed lists of all system specifications in an easy-to-follow table format.
Note: The following specifications are subject to change without notice.
Electrical Characteristics
Power Supply
Battery Backup
Equipment Specification/Requirements
S-ICX Cabinet 200 - 240V AC
Primary Power -
Input @ AC:
AC Frequency:
Maximum Power Dissipation (VA):
230V +10%
50/60 Hz
336VA
Maximum Peak AC Input Current: 1.4A
DC Voltage Output Specification: +24 volts DC (+26.0 to +27.6 volts DC)
+5 volts DC (+4.9 to +5.3 volts DC)
AEC (8-circuit card that supports single-line devices
such as rotary and DTMF standard phones; FAX
machines; dictation equipment; etc.) -
Ring Voltage:
Ringing Capability:
150 volts p-p
2.0 REN per circuit
Traffic Rating Characteristics: 6 ACS per station system-wide
S-ICX key telephones 3 watts maximum (powered from the S-ICX)
Equipment Specification
Battery Pack: (Part No. VB-44026)
Capacity (with maximum traffic): 15 minutes
Battery Charger Characteristics -
Charger:
Nominal Voltage:
Battery Discharge Cut-Off Voltage:
Constant voltage and constant current charge
27.2 volts
21.0 +
0.3 volts DC
Chapter 6 - Specifications