Linear VMC-1 Intercom System User Manual


 
13
Power Supply Rough-In
TE6D Power Supply
The Power Supply unit is pre-wired and self contained, and
the wires are tucked inside. To access connection wires, open
the Power Supply unit by removing four screws as shown
in Figure 6. In the unlikely case that the TE6D electrical
connectors become unplugged, the 3-pin and 6-pin connector
blocks can be re-installed in their respective locations on the
power supply board. Plug connectors in as shown.
WARNING
ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE TE6D
POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN
AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL
CODES
WHT
BLK
1
2
3
PRE-WIRED SELF CONTAINED TE6D POWER SUPPLY
TOP HOUSING
BOTTOM HOUSING
REMOVE 4 SCREWS
TO ACCESS POWER
SUPPLY WIRES
STRAIN RELIEF
STRAIN RELIEF
TOP HOUSING
BOTTOM HOUSING
3-PIN
CONNECTOR
6-PIN CONNECTOR
1
2
3
4
5
6
RED
BLACK
Power Supply Connections
The 6-pin connector is the low voltage (13.8 VDC, 3.8 amp)
output from the TE6D Power Supply unit:
Position 3 is the Black Negative connection for the Master
Station
Position 5 is the Red Positive connection for the Master
Station
The 3-pin connector is for the 110/120 High Voltage input:
Black wire is position 1
White wire is position 3
Figure 6. Opening TE6D Power Supply