Kenwood TH-G71A Two-Way Radio User Manual


 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
REVERSE FUNCTION
When used while monitoring a repeater, the Reverse
function allows you to manually check the signal strength
of a station accessing the repeater. If the station’s signal
is strong, it is best to move to a simplex frequency to
continue the contact and free up the repeater.
Press [REV] to switch the Reverse function ON (or
OFF).
The receive frequency and the transmit frequency are
exchanged.
“R” appears when the function is ON.
Note:
If pressing
[REV]
places the transmit frequency outside the allowable
transmit frequency range, an error beep sounds when
[PTT]
is
pressed, and transmission is inhibited.
If reversal would place the receive frequency outside the receive
frequency range, an error beep sounds when
[REV]
is pressed. No
reversal occurs.
Automatic Repeater Offset does not function while Reverse is ON.
You cannot switch Reverse ON or OFF while transmitting.