SP-1
SPECIFICATIONS
GENERAL
Communication System Simplex, semi-duplex
Frequency Range 1.6 to 27.5 MHz (transmit),
0.1 to 29.9 MHz (receive)
Frequency Resolution Transmit: 100 Hz Receive: 10 Hz
Class of Emission J3E SSB, suppressed carrier, signal channel containing ana-
logue information
H3E SSB, full carrier, signal channel containing analogue infor
mation, telephony; when 2182 kHz is first selected, H3E is
set.
J2B for DSC, NBDP; SSB, suppressed carrier, signal channel
containing quantized or digital information with the use of
a modulating sub-carrier, telegraphy for automatic recep-
tion
F3C weather facsimile, reception only
Frequency Error ±10 Hz (Both Transmitter and Receiver)
Number of Channels Custom channels: 199 max. Programmed by FURUNO autho-
rized service representatives (user may program Rx channels).
ITU SSB/TELEX Channels as listed in the APPENDIX.
2182 kHz (single action)
Environmental Transceiver unit: -20°C to +55°C
Antenna coupler: -30°C to +70°C
Relative humidity 93% at 40°C
Power Supply 13.6 VDC (+15%, -15%)
Receive: 1.5 A
Transmit (max.): 30 A
Radiotelephone Alarm Signal Generator
Two tones of 2200 Hz and 1300 Hz transmitted alternately.
TRANSMITTER
Output Impedance 50 ohms
Output Power
J3E/H3E: 1.6 to 23 MHz, 150 W pep, 23 to 27.5 MHz, 75 W pep
J2B: 1.6 to 23 MHz, 100 W; 23 to 27.5 MHz, 50 W pep
Tune 10 W approx.
Power Reduction 60 W approx.
Controls Output HI/LOW, test (option)/send of two-tone alarm generator