3-1
3. CHANGING SYSTEM SETTINGS
3.1 System Setup
1. While pressing and holding down the [CH] key, turn on the power. Release the [CH] key
when “MEMO” appears on the display.
MEMO
System code
Setting value
Figure 3-1 System setting selection screen
2. Turn the [FREQ/CH] control to select a desired code number.
3. Press the [CH] key, enter desired setting by a numeric key, then press the [ENT] key.
4. To change setting for another code, repeat steps 2 and 3.
5. Reset the power.
3.2 Customizing by User
The operator can customize several system settings. The table below shows the system codes
and their function, setting range and factory setting.
Note: FURUNO Electric Company will assume no responsibility for the inconvenience or
disturbance to communications due to inadequate or unlawful presetting of this equipment.
Code Function, Setting
9942 Key beep ON/OFF
A beep sounds when a keying sequence is correctly executed. You may turn
the beep on or off.
Factory setting: ON
9943 Noise blanker ON/OFF
The noise blanker cancels unwanted noise.
Factory setting: ON