Aiphone 0311 A OI Intercom System User Manual


 
- 41 -
GT-DA-L/GT-DA
Performing settings from an entrance station (Unit type)
Performing settings from an entrance station (Integrated type), security guard station
Link check5-9
Press the program switch of the GT-DA-L/GT-DA for at least 5 seconds.
The in use LED will light up after blinking.
GT-SW: Press the relevant call button.
GT-NS-V/GT-NS: Select the room and press the
button.
An electronic sound will be emitted once if the link is normal. If the link
is abnormal, an error sound will be emitted.
Enter the program mode and select "VERIFY PROGRAM".
Select the room and press the
button.
With a security guard station, an electronic sound will be emitted once if
the link is normal. If the link is abnormal, an error sound will be emitted.
With an entrance station (Integrated type), "CORRECT" will display if
the link is normal and "ERROR" will display if it is not normal.
GT-MKGT-DMV/GT-DM
101
SMITH
VERIFY PROGRAM
VERIFYING...
MENU
:ENTER
VERIFY PROGRAM
SCROLL SPEED
MONITOR ENTRANCE
:QUIT
VERIFY PROGRAM
VERIFYING...
:QUIT
VERIFY PROGRAM
:VERIFY
ROOM NO. 101
SMITH
Next menu item
GT-DMV/GT-DM GT-DMV/GT-DM
:QUIT
VERIFY PROGRAM
CORRECT
:QUIT
VERIFY PROGRAM
ERROR