3Com V7000 Telephone User Manual


 
Configuration Files 329
gateway continues to work with the last active proxy until a proxy failure
occurs.
ALTROUTINGTEL2IPENABLE = 1
Alternate routing of calls is possible if the initial destination cannot be
pinged or if poor quality of service (QoS) is detected. Possible values are:
0 — Disable alternate routing.
1 — Enable alternate routing
2 — Provide read-only information on the quality of service of the
destination IP address. Alternate routing is disabled.
ALTROUTINGTEL2IPMODE = 3
If alternate routing is enabled, select an alternate routing mode. Possible
values are:
0 — Alternate routing is not used.
1 — Alternate routing is performed if a ping to the initial destination
fails.
2 — Alternative routing is performed if a poor quality of service is
detected.
3 — Alternative routing is performed if either a ping failed or poor
quality of service was detected.
GWAPPDELAYTIME = 0
Specify, in seconds, the amount of time that the gateway’s operation is
delayed after a reset cycle. The default value is 0 (zero). NOTE: Increasing
the delay can overcome connection problems caused by some LAN
routers.
DISCONNECTONBROKENCONNECTION = 0
Enable (1) or disable (0) the disconnection of a call if RTP packets are not
received for a defined time period (see BrokenConnectionEventTimeout).
The default timeout value is 10 seconds. This feature cannot be used if
silence compression is enabled.
SENDINVITETOPROXY = 1
Enable (1) or disable (0) the sending of INVITE messages (that are
associated with Transfer or Redirect actions) to the proxy, rather than
directly to the URL. This feature cannot be used unless a SIP Proxy is used
and the parameter “AlwaysSendtoProxy” is disabled (0).