RTM-ATCA-SXXX Overview
6806800H62B ATCA‐S201InstallationandUseGuide25
Note: If no DHCP server is present, the ATCA-S201 will deactivate this port. The
serial console must be then used to manually assign an IP address. This manual
initialization procedure is described in section 3.6 of this manual.
3.4.3 Management Configuration via HTML browser
Once the IP address of the Ethernet port is known, an administrator may use a web
browser to connect to the
ATCA-S201 to perform and monitoring or configuration
tasks. For security, the browser must support secure https connections on TCP port
443.
Example: Type this address into the address field of your web browser:
https://192.168.1.xxx
Refer to chapter 4 , which begins the explanation and use of the html configuration
tool.
3.4.4 Management configuration via secure shell (SSH)
Once the IP address of the Ethernet port is known, an administrator may use a SSH
service to connect to the
ATCA-S201 and to facilitate command line management.
For example:
ssh 192.168.1.211 –l admin
3.4.5 Management configuration via serial console shell
If the boot is not interrupted and has completed, the RS232 port accepts
administrator login for Linux shell access, and access to command line configuration
tools.
*******************************************************
* *
* Welcome to the Emerson ATCA-S201 Storage Blade *
* *
* Type atca_blade to manage this blade, or use the *
* Web Based Management tool by browsing to: *
* https://ipaddr, where ipaddr is the network address *
* of the blade. *
* *
*******************************************************
WebHost.WebDomain login: admin
Password:admin
After successful login, the user may run any the shell configuration tools presented
in section 3.4.5.