Message Description Action
No IP Address Invalid IP. Check the IP address of the handset and re-
configure if required.
This indicates the handset cannot find
any access points due to:
No radio link. Verify that the AP is turned on.
No ESSID – Auto-learn not supported (or)
Incorrect ESSID.
Verify the ESSID of the wireless LAN and enter
or Auto-learn it again if required. See
NetLink
Wireless Telephone Configuration
section
.
AP does not support appropriate data
rates.
Check the AP configuration against
Configuration Guide
for AP.
No Net Found
Out of range. Try getting closer to an AP. Check to see if
other handsets are working within the same
range of an AP. If so, check the ESSID of this
handset.
Incorrect Security settings. Verify that all the security settings in the WT
match those in the APs.
No Net Found
xxxxxxxxxxxx yy
x…x = AP MAC address
yy = AP signal strength
Handset cannot find a suitable access
point; displays MAC and signal strength
of “best” non-suitable AP found.
Check AP and handset network settings such
as ESSID, Security, Reg domain and Tx power.
Ensure APs are configured per
Configuration
Guide
.
Try Site Survey mode to determine more
specific cause.
No Reg Domain Regulatory Domain not set. Configure the Regulatory Domain of the
handset.
No PBX No communication with host telephone
system.
Displays before the system has synchronized
ports with the host telephone system. Should
disappear when the ports are correctly wired
and programmed.
Make sure the proper PBX switch has been
selected within the NetLink Telephony
Gateway.
No SW found A required software component has not
been identified.
Check that the correct software has been
downloaded and is available.
Server Busy Handset is attempting to download from
a Download Master that is busy
downloading other handsets and refusing
additional downloads.
None. The handset will automatically retry the
download every few seconds.
SKT Open Failed Socket open fail. Occurs when the
handset tries to connect to the PBX but
there is no response. If resiliency is
active, the handset will keep trying.
If the PBX is inoperative and resiliency is not
active or the handset cannot locate a backup
PBX, turn off the handset and repair the
primary PBX. Note that it may be advisable to
reconfigure the backup PBX to be the primary
PBX if the repair is more time-consuming than
the reconfiguration.
Storing Config Handset is storing changes to handset
configuration.
None. Informational only. The handset may
display this briefly following a configuration
change or software download.