Chapter 5. Maintenance and Troubleshooting Section 520 - TSAPI
20 Issued April 2000 DBS-92-520
TDILOGERROR(dname, FATAL, ALMLOC, alarmcnt++, "Driver
exiting.", OurName).
This alarm is generated when the CSTA network handler task has
been told to shut down. It indicates that Panadrvr is no longer
available for CSTA services.
TDILOGERROR(dname, FATAL, ALMLOC, alarmcnt++, "Driver
unloading via signal handler.").
This alarm indicates an abnormal Panadrvr termination.
“WARNING” Messages:
TDILOGERROR(dname, WARNING, ALMLOC, alarmcnt++, "Buffer
High Water Mark Reached\n").
The Novell Tserver has told Panadrvr that memory resources are
getting low.
“CAUTION” Messages:
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "DBS
return from Level 1 failure.").
The DBS has returned from a level 1 (1st failure) failure situation.
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "DBS
back on line.").
The DBS has returned from a level 2 (full failure) failure situation.
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++, "DBS
deadman timer fail (DBS is on alert).").
The DBS did not respond to Panadrvr’s keep alive packet. Panadvr
will wait 60 seconds and try again.
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++,
"Received unknown ACS request(0x%0x).", idc->messageType).
Panadrvr received an unknown ACS request from either a client
application or the Novell Tserver itself. This should be reported to
Panasonic Technical Support for investigation.
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++,
"Received unknown packet type (0x%0x) from DBS.", rpp->code).
The DBS has transmitted a packet of unknown meaning to Panadrvr.
This should be reported to Panasonic Technical Support.
TDILOGERROR(dname, CAUTION, ALMLOC, alarmcnt++,
"Received unknown tone event (0x%0x) from DBS.", etp->sublow).
The DBS has sent Panadrvr a Tone Event that Panadrvr does not
understand. This should be reported to Panasonic Technical Support.