Panasonic KX-TDE100 Wireless Office Headset User Manual


 
1.4 Specifications
Installation Manual 37
Note for KX-NT265 IP-PT users
The supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the
version, follow the procedure below:
Power Supply Unit Selection
The PBX needs a power supply unit (PSU) suitable for its configuration. Calculate the load figure from the
type and number of items of equipment to be connected, and determine the type of PSU that will be
required.
Load Figure Calculation
Equipment Type Load Figure
PT KX-T7600 series DPT/KX-T7600 series DSS
console
1
KX-T7560/KX-T7565 DPT 1
Other DPT/Other DSS console 4
APT 4
IP-PT 0
SIP Extension 0
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the load figures.
DHLC8 8
SLC8 8
SLC16 16
MSLC16 16
Basic CS (1 unit) 4
High-density CS (1 unit) 8
ISDN Extension 2
VPS (1 port) 1
"AP Version".
Select
"Maintenance".
Software version
is displayed.
While starting up
Select
"Version display".
To exit the programming mode
PROGRAM
SP-PHONE
SP-PHONE
SP-PHONE
HOLD HOLD HOLD HOLD