Nortel Networks FastRad Telephone User Manual


 
10
FastRAD Installation Guide
Programming
the FastRAD
Before you start, make sure you have completed the
FastRAD
Programming Record
found at the end of this guide. This
record must include the System ID, Auto-answer line number
and Alarm reporting line number.
Table 2 shows the different programming parameters and their
default values. If your programming information does not
specify a value for one of the fields, assign it to the default
value.
Note
: You must program the Required fields for the FastRAD to
operate. Also program any Optional fields that apply to your
system. Auto-answer should be set to ON if unassisted remote
access to the FastRAD is desired.
Table 2 – Programming parameters and default values
Programming Field Range Required / Optional
Default
Password 8 to 10 digits Required none
System ID Up to 10 digits Optional blank
Auto-answer line number 1 - 999 Required for auto-answering Line 001
Alarm reporting line number 1 - 999 Required for alarm reporting Line 001
Local baud rate 300/1200/2400/4800/
9600/19200
Optional 9600
Auto report alarms ON, OFF Optional OFF
Alarm number 1 up to 16 digits Optional blank
Alarm number 2 up to 16 digits Optional blank
Retry delay 1 - 99 minutes Optional 15 minutes
Number of retries 0 - 9 Optional 5
Alarm reporting baud rate Low/Medium/High Optional High
Alarm reporting parity None/Odd/Even Optional None
Auto-answer ON, OFF Optional OFF
Answer delay 6 to 60 seconds Optional 18 seconds
855601 Book : 855601 Guide Page 10 Wednesday, October 29, 1997 4:06 PM