Wire the Antenna Cables
Follow these steps to connect the antenna to the
control unit and the modem.
NOTE: A system wiring diagram is provided in
Appendix A on page 27.
a. First dress the data and power cables from
the antenna. Strip back the insulation of each
wire approximately 1/4" (6 mm) and gently
twist each wire to ensure a good electrical
connection.
b. Find the terminal strip connector in the
kitpack. Connect the antenna data cable to
the terminal strip connector as shown in
Figure 25.
c. Connect the power cable from the antenna to
the terminal strip connector as shown in
Figure 25.
d. Plug the terminal strip connector into the rear
panel of the control unit (see Figure 26).
e. Connect the RF coax cable labeled “RX”
(connected to the antenna’s MRx jack) to the
“Rx RF” jack on the back of the modem (see
Figure 27).
f. Connect the RF coax cable labeled “TX”
(connected to the antenna’s MTx jack) to the
“Tx RF” jack on the back of the modem.
12 1110987612543
Data
Power
Antenna
Blue/White
White/Blue
Brown/White
White/Gray
Gray/White
White/Orange
Orange/White
White/Brown
Red
Black
Terminal Strip Connector
Figure 25: Antenna Power and Data Wiring
The diagram refers to wires by body color/
stripe color. For example, “Brown/White”
means the brown wire with the white stripe.
IMPORTANT!
19
8
7
6
5
4
3
2
1
211
1
0
Control Unit
Terminal Strip
Connector
Antenna
Figure 26: Antenna Power and Data Wiring
Antenna
MRx
J1
AC PWR
J3
Rx RF
J2
Tx RF
J4
ACU
J5
CONSOLE
J6
BUC PWR
J8
USER
ENET
J7
ACU
ENET
MODEL: VMBR-1510 ArcLight
PART: 1234567 REV XXX
SERIAL: XX-XXXXXX
CAGE CODE: 12345
Modem
MTx
TxRFRxRF
Figure 27: Antenna RF Transmit and Receive Wiring
Be sure to terminate RF cables properly with
type “F” connectors.
IMPORTANT!
Wire the Belowdecks Units