5
Computer Setup
The values in those fields are set during
installation.
The Computer name must be changed if a
database from another installation is restored to
this database.
Important: The name in “queue” field must not be
the same as the name in the “Computer” field.
The “queue” field must have the format :
“Computer_name-SW6000”
6
Port Setting
This window is used for changing the
communication properties of the CU
6005/6010/6011.
Make the changes, click ‘Update’ and then click
‘Next’.
7 By selecting a Com port and Click ‘Select’ the
CUI application starts with connection to the port
chosen.
Command line parameters for the CUI
-W Show a communication window when the CUI is started. Don’t use
this parameter in normal use.
-COMx Specifies the COM port to use. COM1 to COM4 are valid entries.
When the COM port is specified, the ‘Select COM port’ popup is
disabled.