Datalogic Scanning STARGATE Two-Way Radio User Manual


 
STAR H GATE™
1
1.4 RESET BUTTON
This button deletes all RAM data restoring the last saved configuration.
By pressing it for 2.5 seconds the yellow light starts blinking and it goes on by
releasing the button. This light signals that STARGATE™ has entered the firmware
downloading mode. While working in this mode the base station current configuration
is deleted and substituted with the default one (Base station
address = 2000; interface = RS232). Then, it is possible to download the firmware
update through the dedicated software running on the PC. If the downloading occurs
successfully, the program will be launched directly by the system.
CAUTION
By pressing the Reset button for 2.5 seconds the base station
current configuration will be deleted.
1.5 DATA BACKUP
A backup of the data saved to STARGATE™ RAM memory is available in case of
power going down. STARGATE™ maintains the data for a maximum of 3 hours.
Then, data is definitely lost.
This feature is only available from the software release 1.10 referring to the software
running on the base station and displayed when enabling the Alive button in RS232
connection (see step 8 in par. 4.3).