Monitoring
You can monitor a door station or multiple door stations in your
site sequentially (scan-monitoring) with a master station.
When monitoring, you can view the image at the station and
hear the sound.
Monitoring
Search for and select the door station in your site that
1
you want to monitor (so that it is highlighted) in one of
the search methods. (P. 27-32)
NOTE:
You cannot monitor a master station and remote site.
Press
2
MONITOR
(when "
[ ]
MONI" is displayed).
Press
3
OFF
to nish monitoring.
NOTES:
If the selected station is being used (calling, communicating, being
monitored, etc.), you cannot monitor the station.
If you press
TALK
or lift the handset while monitoring, the
communication mode starts with the station after a tone.
During video monitoring, you can switch Zoom/Wide, make Pan
& Tilt control and adjust images on the monitor. (
P. 23-24)
To shift to scan-monitoring
Press
MONITOR
during monitoring.
If the station being monitored is a preset one for scan-
*
monitoring, the scan-monitoring starts from the subsequent
station in the scan-monitoring order.
If the station being monitored is not a preset one for scan-
*
monitoring, the scan-monitoring starts from the rst station in
the scan-monitoring order.
Scan-monitoring
You can monitor the preset stations in your site (up to 20 door
stations) sequentially, each for the set duration.
The stations should be preset in the System setting on a PC.
*
Press
1
MONITOR
in the standby mode.
The stations set for scan-monitoring are monitored
sequentially, each for the set duration.
If the scan-monitoring lasts 10 minutes, the backlight of
*
the master station monitor will be turned off.
Pressing any key will turn on the backlight again.
If the scan-monitoring target station is only one, the scan-
*
monitoring ends after a lapse of approx. 11 minutes.
Press
2
OFF
to stop scan-monitoring
.
To monitor only the desired station continuously:
Press
MONITOR
when the target station is being
monitored during scan-monitoring.
Press
*
MONITOR
again to restart the scan-monitoring.
NOTES:
Pressing
TALK
is invalid during scan-monitoring.
If the handset is lifted during scan-monitoring, the scan-monitoring
is continued and sounds at the target station can be heard from the
handset, and when the handset is hung up or
OFF
is pressed, the
scan-monitoring ends.
If the master station receives a call during scan-monitoring, the
scan-monitoring ends automatically.
If one of the preset stations is being used (calling, communicating,
being monitored, etc.) during the scan-monitoring, it will be
skipped.
During the scan-monitoring, the Zoom/Wide, Pan & Tilt, door
release and image adjusting functions are disabled. (The camera is
xed in the Wide mode.)