416 APPENDIX C: REPLACING A FAILED DISK ON A VCX SERVER
cd /opt/3com/VCX/scripts/rc3.d
./S70tomcat stop
2 On the Authentication and Directory server in the regional office that is
associated with this branch office, drop replication for the database for
this branch office.
a Log in as cworks.
b Enter these commands:
cd /opt/3com/VCX/vcxdata/bin
./dropReplication
c Enter the site ID for the branch office.
3 Replace the failed disk on the branch office server.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
4 Log in as root and configure networking parameters on the down server
by entering this command:
vcx-config-network --wizard
If the down server is the primary VCX server, follow the instructions in
“Configuring an IP Telephony Server at a Branch Office” in Chapter 3.
5 If necessary, upgrade the software on the down server to match the
software version on other branch office servers.
a Compare the software version on the down server to the software
version on another branch office server.
On the other branch office server and on the down server, enter this
command:
vcx-showversion
b If the down server is running an earlier software version than the other
branch office server, download the appropriate software upgrade file
to the
/opt/installtemp directory on the down server.
The location of the software upgrade file depends on 3Com’s service
delivery methods and on the customer network configuration.