3Com V7000 Telephone User Manual


 
408 APPENDIX C: REPLACING A FAILED DISK ON A VCX SERVER
./S70tomcat start
c On the Call Processing Server in the local regional office, log in as root.
d Enter these commands:
cd /opt/3com/VCX/scripts/rc3.d
./S70tomcat start
e On each branch office server, log in as root.
f Enter these commands:
cd /opt/3com/VCX/scripts/rc3.d
./S70tomcat start
This marks the end of the outage.
Replacing a Call
Records Server Disk
Each multi-site VCX system has one Call Records Server that is located in
one of the regional offices. Use the instructions in this section to replace a
failed disk on a Call Records Server.
If this server is configured for RAID operation, see RAID Disk Failure,
earlier in this appendix.
1 Replace the failed disk.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
2 Configure the networking and services parameters on the down server
using this command:
vcx-setup
For detailed instructions, see “Configuring a Call Records Server” in
Chapter 6.
3 After the setup has been completed, update the Call Records Server with
the IP addresses of the Accounting Servers from which it must collect call
records. See “Adding Accounting Servers to the Call Records Server” in
the VCX Administration Guide.
This marks the end of the outage.