Polycom SIP 2.2.2 Telephone User Manual


 
Configuration Files
A - 81
Main Browser <main/>
This setting controls the home page used by the Microbrowser when that
function is selected.
Browser Limits <limits/>
These settings limit the size of object which the Microbrowser will display by
limiting the amount of memory available for the Microbrowser.
Attribute Permitted Values Default Interpretation
mb.main.home Any fully formed valid
HTTP URL. Length
up to 255 characters.
Null URL used for Microbrowser home page. If blank,
the browser will notify the user that a blank
home-page was used.
For example:
http://www.example.com/xhtml/frontpage.cgi?pa
ge=home.
mb.main.statusbar 0, 1 Null Flag to determine whether or not to turn off
display of status messages.
If set to 1, the display of the status bar is
enabled.
If set to 0, or Null, the display of the status bar is
disabled.
mb.main.idleTimeout 0 - 10, minutes Null Timeout for the interactive browser. If the
interactive browser remains idle for a defined
period of time, the phone should return to the
idle browser.
If set to 0 or Null, there is no timeout.
If set to value greater than 0 and less than 10,
the timeout is for that number of minutes.
Attribute Permitted Values Default Interpretation
mb.limits.nodes positive integer 256 Limits the number of tags that the XML parser
will handle. This limits the amount of memory
used by complicated pages. A maximum total of
500 (256 each) is recommended. This value is
used as referent values for 16MB of SDRAM.
Note: Increasing this value may have a
detrimental effect on performance of the phone.
mb.limits.cache positive integer 200 Limits the total size of objects downloaded for
each page (both XHTML and images). Once this
limit is reached, no more images are
downloaded until the next page is requested.
Units = kBytes. This value is used as referent
values for 16MB of SDRAM.
Note: Increasing this value may have a
detrimental effect on performance of the phone.