Polycom Mitel Networks 3300 Cordless Telephone User Manual


 
SpectraLink Corporation Configuration and Administration—NetLink e340/i640 Wireless Telephone
Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation
PN: 72-1084-02-G.doc Page 59
Message Description Action
TFTP ERROR(x):yy A failure has occurred during a TFTP software
download. (x) = The file number which was
being downloaded; yy is an error code
describing the particular failure. Possible
error codes are:
01 = TFTP server did not find the requested
file.
02 = Access violation (reported from TFTP
server).
07 = TFTP server reported "No such user"
error.
16 = No TFTP server address.
81 = File put into memory did not CRC.
FF = Timeout error. TFTP server did not
respond within a specified period of time.
Error code 01, 02, 07, or 16 - check the
TFTP server configuration.
Error code 81, the handset will attempt to
download the file again.
For other messages, power off the handset,
then turn it on again to retry the download.
If the error repeats, note it and contact
SpectraLink Technical Support.
Too Many Errors The handset continues to reset and cannot
be recovered.
Fatal error. Return handset to SpectraLink.
Unknown
xx:yy:zz
A phrase is missing from your phintl file. Download new software from the
SpectraLink site per
Software
Maintenance
.
Updating … The handset is internally updating its
software images
None. The handset may do this briefly after
a download. This is informational only.
Updating Code… Handset is downloading new software into
memory. The number icons at the bottom of
the display indicate which file number is
currently being downloaded. This message
also displays a progress bar. When the
progress bar fills the display line the update
operation is complete on that file.
None. When the progress bar fills the
display line the update operation is
complete on that file.
Do not turn the handset off during this
operation.
Waiting… Handset has attempted some operation
several times and failed
None. The handset is waiting for a
specified period of time before attempting
that operation again.
Watchdog Timeout The handset failed to hear from the
supported Mitel Networks VoIP solution
within the watchdog timeout interval.
Verify the supported Mitel Networks VoIP
solution is operational and connected to
the network.
Wrong Code Type The software loaded into the handset is
incorrect for this model phone
Replace the software image on the TFTP
server with software that is correct for the
phone model.