Omega OMA-P1104 Cordless Telephone User Manual


 
Omegaphone
®
OMA-P1104 User’s Manual
50
For example, if a magnetic reed switch (a normally-closed
sensor used to detect unauthorized entry) has been wired
to the OMA-P1104, make sure that the door or window to
be monitored is shut before configuring the input. If a
motion-detector is wired to the unit, it is advisable to
block all sources of motion from the sensor before and
during configuration.
5.1.1 Programming Input Configuration
1. Press STANDBY to place the OMA-P1104 in
Standby mode.
RUN
STANDBY
2. Wire sensors to the inputs to the back of the OMA-P1104
(see Chapter 2, Section 2.10).
3. Press RUN. The red light glows when the OMA-P1104
returns to Run mode.
RUN
STANDBY
4. Press SET.
SET
#
5. Press CONFIGURE.
STATUS
CONFIGURE
6. The OMA-P1104 audibly recites the configuration for
each of the four inputs:
If the input is normally open, the OMA-P1104 recites
the number of the input and says“OK.”
If the input is normally closed, the OMA-P1104 recites
the number of the input, followed by a “beep”
and“OK.”