Mitel SX-2000 Telephone User Manual


 
SX-200 General Information Guide
214 Revision A 50003510
Site
SX-200 IP Node
Temperature 0º C to 40º C (32º F to 104º F)
Humidity 15 to 95% Relative Humidity, non-condensing
Vibration 0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis
Mechanical
Stress
One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest face –
unpackaged
One 76.2 cm (30 in.) drop, each edge and corner packaged in
cardboard & foam.
Site Conditions
SX-200 EL/ML System
Operating Temperature 0 to 40º C 32 to 104º F
Relative Humidity (Operating)
(non-condensing)
20 to 80% 20 to 80%
Heat Dissipation (approximate) 500 BTUs / hr
Maximum Altitude 4000 m 13,000 ft.
SX-200 IP Node
Operating Temperature 15º to 35º C 59º to 95º F
Relative Humidity (Operating)
(non-condensing)
40 to 90%
Heat Dissipation - fully loaded* 724 BTUs/hr
Air Flow 150 cubic feet per minute at
maximum output of the fans
Acoustic Emission Maximum 50 dBA continuous, 75
dB intermittent (<10% duty cycle)
* Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000
BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration
Storage Conditions (continued)
Specification Range