Mitel SX-2000 Telephone User Manual


 
50003510 Revision A 213
Specifications
By offering a balanced set of features and system configurations, the SX-200 EL/ML system
becomes an ideal communications center for installations of up to 650 telephones. This
translates into a system with the power and flexibility to meet today’s needs that is easily
expanded to accommodate tomorrow‘s changing requirements.
Nonblocking digital bays, busy hour call attempts (BHCA) to 2765, and traffic capacity
exceeding 3400 CCS make sure that the SX-200 EL/ML system is available when you need it.
Environment
The SX-200 EL or SX-200 ML system should be located in an area that is dry, clean, well
ventilated, well lit, and readily accessible.
Shipping
The equipment is designed to withstand shipping by truck, rail, air, or sea without damage,
when packaged in conventional shipping containers supplied by the manufacturer.
Storage
The following table lists the range of environmental conditions that the equipment is capable
of withstanding in storage.
Storage Conditions
Specification Range
SX-200 EL/ML System
Temperature
Range
-20º C to 66º C (-4º F to 150º F) for the SX-200 system
-40º C to 66º C (-40º F to 150º F) for the SX-200 SPINE bay and modules
-20º C to 60º C (-4º F to 140º F) for the console
Relative
Humidity
5 % to 95% RH at 18º C (64.4º F) non-condensing
10% to 70% RH for the console
Vibration 0.5 g (4.903 m/s2) (sinusoidal) 5 to 100 Hz
1.5 g (14.7 m/s2) (sinusoidal) 100 to 500 Hz
Shock Up to 75 cm (30 in.) drop depending upon package
Mechanical
Shock
Up to 61 cm (24 in.) drop on any face or corner
Up to 75 cm (30 in.) drop of SPINE bay and modules
Low Pressure 87 mm Hg 15,152 m (50,000 ft)
Temperature
Shock
-40º C to 21º C (-40º F to 70º F) in 5 minutes
66º C to 21º C (150º F to 70º F) in 5 minutes
Page 1 of 2