Link electronic Door phone Telephone User Manual


 
16
50
p
Pause duration (ms)
8
(800ms)
8
(800ms)
8
(800ms)
6# s
Number of fitted buttons
on basic module
6* t
Delay of line connection
(Siemens PBX)
1 1 1
6 z
Acoustic signalling
3 and 9 3 and 9 3 and 9
8# #
Default setting
executes
8# 1
Setting per exam. 1
executes
8# 2
Setting per exam. 2
executes
81
Deletes all numbers in
group 1 (Day mode)
82
Deletes all numbers in
group 2 (Night mode)
83
Default setting only
for parameters 3x
only 3..
84
Default setting only
for parameters 4x
only 4..
85
Default setting only
for parameters 5x
only 5..
9
E N D
6 Technical parameters
6.1 Electrical parameters
Parameter Value Conditions
Minimum line current 18mA line answered
Minimum line voltage 18V line hang up
Voltage on line while off hook
(VA characteristics)
< 8V
< 12V
I = 20mA
I = 60 mA
Leakage in hang up status < 50uA U = 60V
Impedance of line termination
130R +
820R paral. 220n
line answered
Bandwidth 300Hz – 3400 Hz 20 - 60mA
Impedance of ringing > 2Kohm 25 – 60 Hz
Sensitivity of ringing detector min. 10 – 25 V
Pulse choice 40 / 60 ms
Tone choice level 4 - 6 dB 20 – 60 mA
Tone choice sensitivity 40 dB 20 – 60 mA
Sensitivity of tone detector 30 dB 20 – 60 mA
Power supply of lighting through,
switches and heating
12V ± 2V , 10-12V ± 2V
Max. consumption of lighting
through and heating
300mA 12V
Max. voltage of switch contact 48V at I < 1A
Max. current of switch contact 2A at U < 30 V
Operational temperature - 20 to + 50°C
6.2 Mechanical dimensions
Dimensions WxHxD 104mm x 153mm x 16mm
Weight 360g
Unit material elox aluminium profile
Name card panel material acrylglas (plexiglass)