d – maximum time in minutes for which a call may last. This time can be extended
during a call by dialling Prolong Call digit from telephone (or #). Time setting is
per table.
Parameter Value Description Default Exam.1 Exam.2
53 w
time between button
presses
2 2 2
w max. time [sec] between button presses [range 1-9]
- relay closing – if time between two next presses is bigger than w time, the code is not
evaluated correctly.
- dialling – if the button pressed is the first password number for switch closing, so the choice is
delayed by this w time.
Parameter Value Description Default Exam.1 Exam.2
54 z
On hook time before new
call
2 2 2
z – time [sec] for which the unit will hang up, before repeat dialling (button pressing during call or dialling,
busy tone detection) [range 1-5]
Parameter Value Description Default Exam.1 Exam.2
55 z
Call start time
1 1 1
z – time [sec] after unit goes on hook before dialling [range 1-5]. This time is different for each PBX, but
most PBXs usually manage to process dialling up to 2 seconds after line on hook.
Parameter Value Description Default Exam.1 Exam.2
56 h
Number of rings before
hanging up or group mode
switching
12 12 12
h – specifies the amount of time spent ringing before the unit hangs up and tries the next number.
Parameter Value Description Default Exam.1 Exam.2
57 t
DTMF tone duration (ms)
5
(100ms)
5
(100ms)
5
(100ms)
58 m
Space duration between
DTMF tones (ms)
5
(100ms)
5
(100ms)
5
(100ms)
59 f
Recall duration (ms)
1
(100ms)
1
(100ms)
1
(100ms)
50 p
Pause duration (ms)
8
(800ms)
8
(800ms)
8
(800ms)
t – DTMF tone duration is determined by the formula:
(entered number + 5) x 10 = tone duration [ms]
[range 1-0 i.e. 60-150ms]
m
Space duration between DTMF tones is determined by the formula:
(entered number + 5) x 10 = gap duration [ms]
[range 1-0 i.e. 60-150ms]
f – Recall duration is determined by the formula:
entered number x 100 = Recall duration [ms]
[range 1-6 i.e. 100-600ms]
p – Pause duration is determined by the formula:
entered number x 100 = pause duration [ms]
[range 5-0 i.e. 500-1000ms]
time
[min]
choice
0,5 0
1 - 9 1 - 9
15
30 #