z=3 – all tones are active – (default)
It is possible to generate an audible signal (only in mode m=1) to alert visitors that the door is unlocked so
that they can enter. This is especially useful when using a DC power source, as lock release may be silent.
z=8 – signalling is active
z=9 – signalling is unactive
Parameter Value Description Default Exam.1 Exam.2
6
t
Delay of line connection
(Siemens PBX)
1 1 1
Setes a delay for line pick-up (OFF HOOK) for new PBX types (particularly Siemens):
t=1 – standard operation
t=0 – delayed start
5.8 Overview of Parameters
Parameter Value Description Default Exam.1 Exam.2
1 t nn…
No. nn under button t - - -
2 t nn…
No. nn under button t - - -
31 r
Relay mode
1 1 2
32 hhhhhh
External access code in
DAY + NIGHT mode
- 2211 1324
33 hhhhhh
External access code in
DAY mode
- 2211 2211
34 hhhhhh
External access code in
NIGHT mode
- 1122 1122
35 aa
Internal access code
55 55 55
36 r ss
Relay closing time
05 02 05
41 v
Dialling type
0 0 0
42 z
Proling call
* * *
43 bb
End call
55 55 55
44 xxxx
Password
0000 0000 0000
45 dd
DAY MODE switching
11 11 11
46 nn
NIGHT MODE switching
10 10 10
47 e
Dialling mode
1 1 0
51 q
Number of rings before
pick-up
2 1 2
52 d
Maximum call duration
2 1 4
53 w
Time between button
presses
2 2 2
54 z
On hook time before new
call
2 2 2
55 z
Call start time
1 1 1
56 h
Number of rings before
hanging up or group mode
switching
12 12 12
57 t
DTMF tone duration (ms)
5
(100ms)
5
(100ms)
5
(100ms)
58 m
Space duration between
DTMF tones (ms)
5
(100ms)
5
(100ms)
5
(100ms)
59 f
Recall duration (ms)
1
(100ms)
1
(100ms)
1
(100ms)