p time is simultaneously the duration of interdigit gap at pulse dialling.
5.5 Presetting and Deleting
Parameter Value Description Default Exam.1 Exam.2
8# #
Default setting
executes
8# 1
Setting per exam. 1
executes
8# 2
Setting per exam. 2
executes
This setting does not influence 1 and 2 (numbers stored in memory)
Parameter Value Description Default Exam.1 Exam.2
81
Deletes all numbers in
group 1 (Day mode)
82
Deletes all numbers in
group 2 (Night mode)
83
Default setting only
for parameters 3x
only 3..
84
Default setting only
for parameters 4x
only 4..
85
Default setting only
for parameters 5x
only 5..
The parameters 81 and 82 will delete all numbers stored in memories for buttons.
The parameters 83 – 85 will execute a selective basic setting only for parameters starting with 3.. – 5..
ATTENTION !!!
the deletion is non-reversible!!! Numbers must be programmed again.
5.6 Exit programming
Parameter Value Description Default Exam.1 Exam.2
9
E N D
After dialling 9 the unit will hang up. If you hang up the phone during programming mode without press 9, the
doorphone will stay in programming mode during 20 seconds.
5.7 System setting
Parameter Value Description Default Exam.1 Exam.2
6# s
Number of fitted buttons of
basic module
The basic module is fitted with 4 buttons as standard, i.e. s = 1 is set up for basic module with one button
and s = 2 for module with 2 buttons. This setting is a factory one, no service can change it and so it is
recommended not to change this parameter.
Note: Connecting to the line the value of this parameter is checked and if not satisfactory for unknown reasons, so it is
set up to s = 4 (fitted with 4 buttons).
ATTENTION !!! This parameter can cause the unit to function incorrectly.
Parametr Value Description Default Exam.1 Exam.2
6 z
Acoustic signalling
3 and 9 3 and 9 3 and 9
In default the unit produces acoustic signals. It can occasionally cause a problem of incorrect detection of
tones by PBX. By changing parameter „z“ you can switch off this acoustic signalization. The values are:
z=0 – all signalling is switched off
z=1 – pick up and hang up tones are active only
z=2 – other tones active only
(except pick up and hang up)